Diathermy Loop Electrodes UK: Loop Sizes, Shapes and Shaft Options for Colposcopy and Theatre Supply

Diathermy Loop Electrodes UK

Width, depth, wire, shape and shaft: the five details behind every loop electrode order âž°

Loop electrodes are one of the most size-sensitive items in an electrosurgical stock room. A colposcopy service may hold several loop sizes so the clinician can choose the one that suits each patient, and a theatre may need long-shaft loops for different procedures. When a requisition arrives as “loop electrodes, assorted”, the procurement team has to work out which loops, which shafts and which use status the department actually means.

This guide covers diathermy loop electrodes for UK supply: the loop types Cosil Instruments lists, how loop sizes are described, how to match shafts and handpieces, and what documents and handling information UK buyers should obtain before approval.

Quick answer: Diathermy loop electrodes are monopolar electrodes with a fine wire loop at the working end. Cosil lists round, triangular, rhombic and ribbon loop electrodes in a range of sizes, including long 140 mm and 160 mm versions with loops such as 15 Ă— 15 mm, 15 Ă— 20 mm, 20 Ă— 20 mm and 20 Ă— 25 mm, on 1.6 mm, 2.38 mm, 2.4 mm and 4 mm shafts. Most are available in multi-use and single-use versions in boxes of 50. UK buyers should specify loop shape and size, overall length, shaft and use status for each reference.

Where Loop Electrodes Are Used

Loop electrodes are used in several specialties. In the UK they are perhaps best known in colposcopy services that carry out loop excision of the transformation zone (LLETZ), but loops of different sizes and shapes are also used elsewhere in surgery. The choice of loop for any procedure is a clinical decision.

For procurement, the important point is that loop electrodes are not interchangeable. A clinic that uses three loop sizes needs three references, each with its own stock code and reorder level.

Key insight: Treat every loop size as a separate product. “Assorted loops” on a requisition is a question to send back, not an item to order.

Loop Electrodes in Cosil’s Catalogue

Loop type Examples listed Shafts listed Notes
Round wire loop, standard length 5 mm, 10 mm, 15 mm loops 1.6 mm, 2.38 mm, 2.4 mm, 4 mm Fine wire, e.g. 0.2 mm
Triangular wire loop Several sizes 2.38 mm, 2.4 mm, 4 mm Shape differs from round loops
Rhombic wire loop e.g. 2 Ă— 8 mm 2.38 mm, 2.4 mm Narrow profile
Ribbon loop e.g. 10 mm, 15 mm, 19 mm 2.4 mm, 4 mm Flat ribbon rather than round wire
Long loop electrode 140 mm and 160 mm overall; loops such as 10 Ă— 10, 15 Ă— 15, 15 Ă— 20, 20 Ă— 20, 20 Ă— 25, 25 mm and 30 mm 2.4 mm, 4 mm Overall length and loop size together
Non-stick wire loop 5 mm and 10 mm 2.4 mm, 4 mm Coated working end

Most loop electrodes are listed in both multi-use and single-use versions, packed in boxes of 50 units, with a maximum voltage rating (Umax) of 0.5 kVp. Confirm the exact loop dimensions and reference before ordering.

For the wider electrode range, see our diathermy electrodes for UK buyers and the main diathermy electrode page.

How Loop Sizes Are Described

Loop sizes are written in different ways by different manufacturers, which is a common source of confusion.

  • A single figure (for example 10 mm) usually describes the loop’s width or diameter.
  • Two figures (for example 20 Ă— 15 mm or 15 Ă— 20 mm) usually describe width and depth, but the order is not standard across suppliers.
  • Wire diameter (for example 0.2 mm) may be listed separately.
  • Overall length (for example 140 mm or 160 mm) describes the whole electrode, including shaft.

When converting a clinical request into an order, confirm which dimension is which with the supplier. A photograph or drawing of the loop currently in use, with a ruler alongside, removes most of the ambiguity.

Key insight: For two-figure loop sizes, ask the supplier to confirm which number is the width and which is the depth before you approve the reference.

Matching the Shaft to the Handpiece

Loop electrodes are listed on 1.6 mm, 2.38 mm, 2.4 mm and 4 mm shafts. The shaft must match the pencil or handpiece used by the department. Our guide to diathermy electrode shaft sizes in the UK explains how to identify the size each handpiece accepts, and the cautery pencils for UK theatres page covers the pencils.

Colposcopy services often use a dedicated handpiece. Record its reference against every loop electrode it accepts.

Multi-Use or Single-Use Loops

Loop electrodes have a very fine wire, which can deform or break with use and handling.

Single-use loops give a new loop for every patient and remove the need to reprocess a delicate wire. Confirm sterile status, packaging and batch identification for each reference.

Multi-use loops need reprocessing instructions that cover the wire and the insulation, inspection criteria for loop shape and wire integrity, and clear withdrawal criteria. Share them with sterile services before approval.

Some services choose single-use loops for these reasons, but the decision should follow local policy and decontamination capacity.

Loop Electrodes in a Colposcopy Supply Set

A colposcopy or gynaecology service using loop electrodes usually also needs:

Sourcing these together makes it easier to confirm that every item suits the same generator and handpiece.

UK Documentation and Regulatory Checks

For each loop electrode reference, UK buyers should request the declaration of conformity, labelling and instructions for use, and reprocessing information for multi-use versions. For devices placed on the Great Britain market, UK Responsible Person, MHRA registration and post-market surveillance duties continue to apply. On 21 October 2026 the UK government confirmed it intends to legislate for indefinite recognition of devices CE-marked under the EU MDR, so check the current position at tender time.

Cosil’s website refers to CE certification with SGS Belgium as notified body, ISO 13485:2016 and EUDAMED registration, and notes that MDR certification is in progress. Request current certificates and check their scope. See our quality policy.

Supply Notes for UK Hospitals and Distributors

Hospitals and clinics should set reorder levels for each loop size, based on how often each size is chosen. The most-used size runs out first; the least-used size can expire on the shelf if single-use stock is held in excess.

Distributors can present loops by shape first, then size, then shaft and use status, with dimensions stated in full. Cosil offers OEM and private-label manufacturing and notes that special lengths, tips and colours can be produced to order.

Frequently Asked Questions

Which loop electrodes does Cosil supply?

Cosil lists round, triangular, rhombic and ribbon wire loop electrodes, non-stick loops and long 140 mm and 160 mm loop electrodes, on 1.6 mm, 2.38 mm, 2.4 mm and 4 mm shafts.

Are loop electrodes single-use?

Most loop references are listed in both multi-use and single-use versions. Confirm use status and sterile status for each reference.

How are loop electrode sizes described?

Usually by loop width, or by width and depth, with wire diameter and overall length listed separately. Confirm with the supplier which figure is which.

Will Cosil loop electrodes fit our handpiece?

They fit handpieces that accept the same shaft diameter. Confirm the handpiece’s accepted shaft and choose the matching reference.

How are loop electrodes packed?

Cosil lists its electrodes in boxes of 50 units. Confirm pack format and labelling for each reference.

Can loop electrodes be made to a specific size?

Cosil notes that special lengths and tips can be produced to order. Share a drawing or sample and expected volumes so feasibility can be reviewed.

The Right Loop, Every Time

Loop electrodes are small, delicate and highly size-specific. UK buyers who list every loop size as its own reference, confirm how dimensions are written and match each loop to its handpiece will find that clinicians get the loop they expect, every time.

Sourcing diathermy loop electrodes for UK colposcopy services, hospitals or distribution? Contact Cosil Instruments at sales@cosilinstruments.com or +92 331 732 7777, or send your loop sizes and handpiece details, to request product information and a quotation.